MIL-STD-1246C is the US military standard that defines how clean a component surface must be, by counting particles in set size bands per 0.1 m² and, optionally, weighing non-volatile residue. It was cancelled in 2002 and superseded by IEST-STD-CC1246, but drawings, legacy specifications and defence and space supply chains still cite it. If you buy optical windows, sensor covers or display glass against a “Level 100” or “Level 200” call-out, you need to know exactly what that number promises, how it is verified and how to phrase it so the supplier and your inspector read it the same way.
TL;DR
- MIL-STD-1246C expresses cleanliness as a level (for example Level 100), which caps the particles allowed per 0.1 m² of surface in each size band. Non-volatile residue (NVR) is a separate, optional letter code.
- The standard is recorded as cancelled on 15 February 2002 and superseded by IEST-STD-CC1246. Many drawings still quote the old revision, so state which revision you mean.
- Product cleanliness is not the same as a cleanroom class (ISO 14644-1) or a fluid cleanliness code (ISO 4406). They measure different things.
- A usable RFQ names the level, the NVR level if needed, the surface it applies to, the sampling method and the report you expect.
Table of Contents
- What the standard actually specifies
- How to read a call-out such as “Level 200F”
- Cleanliness level, cleanroom class and fluid code: three different things
- How cleanliness is measured and reported
- Where MIL-STD-1246C still appears, and where it stops applying
- Writing a cleanliness requirement that a glass supplier can quote
- Promo: precision glass built to be specified and audited
- Perspective
- FAQ
- Sources
What the standard actually specifies
The standard’s title is Product Cleanliness Levels and Contamination Control Program. Its scope is to give a uniform basis for specifying product cleanliness levels and contamination control requirements, concentrating on contaminants that cause harm physically rather than chemically. For glass, that means particles that scatter light, scratch a coating, block a sensor aperture or lodge in a bonded joint.
Table I sets particle levels from 1 up to 750, and the revised Notice 1 edition extends it to Level 1000. Each level gives a maximum count per 0.1 m² in each size bin. Level 100, one of the most commonly quoted, allows per 0.1 m²:
| Particle size | Maximum count per 0.1 m² (Level 100) |
|---|---|
| ≥5 µm | 1,930 |
| ≥15 µm | 286 |
| ≥25 µm | 84.2 |
| ≥50 µm | 11.9 |
| ≥100 µm | 1.08 |
These figures come from Table I of the standard. Notice 1 adds the coarse end of the scale: Level 1000 allows 46,100 particles of 100 µm or larger and 1,100 of 250 µm or larger per 0.1 m².
The table is built on a log-log relationship. ESA’s space product assurance standard notes that the levels follow a correlation in which the slope factor of 0.926 is valid only for cleaned surfaces, and that the scale is non-linear, which makes it awkward to budget against. In practice this means a higher level number is not a proportional step: moving from Level 100 to Level 200 changes every size bin by different amounts, so never interpolate.

How to read a call-out such as “Level 200F”
The standard writes a requirement as “MIL-STD-1246 Level X Y, Z”:
- X is the particle level from Table I.
- Y is the NVR level from Table II, shown as a letter.
- Z adds optional limits such as percent area coverage, condensable volatile material or total mass loss.
Per Section 4.2, “Level 200F” therefore means particulate plus NVR, while “Level F” means NVR only. Two further rules matter when you write a drawing note:
- Levels are maximum amounts per unit extent. The measured total is divided by the total surface area inspected. A part smaller than 0.1 m² whose whole critical surface is sampled is judged on its actual count.
- The design organisation selects the level. The producing organisation achieves and maintains it. The level belongs to you, as buyer, to justify; it is not something a supplier can choose for you.
Cleanliness level, cleanroom class and fluid code: three different things
Searchers often mix these up, and so do RFQs. They answer different questions.
| Standard | What it classifies | Unit |
|---|---|---|
| MIL-STD-1246C / IEST-STD-CC1246 | Particles and residue on a product surface | Count per 0.1 m² by size bin; NVR in mg per 0.1 m² |
| ISO 14644-1 | Airborne particles in a cleanroom | Particles per cubic metre of air |
| ISO 4406 | Solid particles in hydraulic or lubricating fluid | Code from counts per millilitre |
An ISO Class 7 room, for example, is limited to 352,000 particles of 0.5 µm or larger per cubic metre of air. That says nothing about what is on a window surface. A part can be handled in an ISO 7 room and still fail a Level 100 surface check if it is cleaned or packed badly. The reverse also holds: a clean part can pick up particles in a poor environment.
ISO 4406 is a three-number code for fluids, based on particles above 4, 6 and 14 microns per millilitre. It matters for hydraulic assemblies, not for the surface of a lens or display cover.
The practical rule: specify the surface with a product cleanliness level, the environment with an ISO 14644-1 class, and keep fluid codes for fluid systems.
How cleanliness is measured and reported
The standard does not leave the method open. It calls for ASTM procedures or demonstrated equivalents: tape-lift sampling to ASTM E1216 for particles and solvent flush or wash analysis for NVR. Results are reported as counts per 0.1 m² by size bin and as milligrams of NVR per 0.1 m², with the sampling details and acceptance criteria documented.
Two points catch buyers out.
Tape lifts and delicate surfaces. ECSS-Q-70-01A sets the tape technique: the tape is applied in one direction with a force below 0.1 N and removed at a constant speed below 1 cm/s at about 45°. It also states that sensitive surfaces shall not be tape-lifted, and that if sensitivity is unknown a representative trial lift must show the surface is not sensitive. Soft anti-reflective or other thin-film coatings are the obvious case on glass. Agree the sampling method for coated faces before the order, not at incoming inspection.
Units. Surface particles are counted per 0.1 m² of significant surface area. NVR is in mg per 0.1 m². Liquids use counts per unit volume to ARP 598, and turbidity is in Nephelometric Turbidity Units, per Section 5.1.1. If your part is a 40 mm window, the whole significant surface is far below 0.1 m², so the count is on the actual part rather than scaled.
For dimensional and optical verification that sits next to cleanliness checks, our guide to precision glass measurement methods covers what each method can and cannot confirm.

Where MIL-STD-1246C still appears, and where it stops applying
The standard was written for military procurement and design contracts where contamination control by measurement of parts, components or fluids is needed for reliability. When it is part of a contract, the procuring activity identifies the applicable requirements. It is not a general commercial rule, and it does not apply to your part unless your contract or drawing invokes it.
It does still turn up. NASA JPL’s quality clause for materials says the test specification for most materials is MIL-STD-1246C, with particulate tests to Notice 1 Table I at a level between 100 and 500, depending on the cleanroom classification where the material will be used. Legacy defence drawings, long-life programme baselines and sub-tier flow-downs carry the same wording.
The status you should write into the RFQ
The US Defense Logistics Agency’s ASSIST-QuickSearch records MIL-STD-1246 as cancelled on 15 February 2002 and superseded by IEST-STD-CC1246. The standard dates from 1962, with a revision B in 1987, and the Army Missile Command commissioned the Institute of Environmental Sciences to revise it. The Institute of Environmental Sciences and Technology (IEST) now publishes IEST-STD-CC1246E, Product Cleanliness Levels: Applications, Requirements, and Determination, first printed in February 2013. It keeps the purpose of the original and separates particle and NVR levels, with alternative level designations in informative annexes.
What that means for you:
- If a drawing says MIL-STD-1246C, the cancelled revision is the contractual reference. Confirm with your customer whether the contract allows IEST-STD-CC1246E as the equivalent, and record the answer.
- Do not assume a Level 100 call-out maps unchanged onto the successor’s designations. Ask your design authority for the intended level in the current standard, and write both on the RFQ if the contract needs both.
- Where a UK defence contract points to a Defence Standard or a SAE AMS-03 cleaning process, those documents govern their own preparatory procedures. SAE AMS-03-2C does not override special procedures in individual Defence Standards and specifications.
Writing a cleanliness requirement that a glass supplier can quote
Most cleanliness disputes are not about the particles. They are about an ambiguous note. A requirement that quotes cleanly contains the following:
- Standard and revision. “MIL-STD-1246C Notice 1” or “IEST-STD-CC1246E”, not “MIL-STD-1246” alone.
- Level and NVR. The particle level, the NVR letter if residue matters, and any optional limits such as outgassing. For outgassing, see our note on ASTM E595 and why old data needs RFQ checks.
- Surface. Which faces are “significant surface”. An optical window usually needs the clear aperture and not the ground edge; say so.
- Point of verification. At the supplier’s dispatch, at your goods-in, or both. Cleanliness is perishable, so a count taken at dispatch does not describe the part after transit and unpacking.
- Method. Tape lift, solvent wash, or an agreed equivalent, with the coating exclusions stated.
- Packaging. Bagging, double bagging, inert purge, and the environment in which the part may be opened.
- Records. What the report must show: lot, sampled area, counts by bin, NVR result and the acceptance criteria used.
Cleanliness also interacts with cosmetic and optical requirements. A particle on a surface can look like a dig, and the reverse. If your RFQ includes both, read our guide to scratch and dig specification with scatter tests so the two criteria do not contradict each other. For medical programmes where residue and bioburden sit alongside particles, the bioburden control buyer’s guide shows how to separate the requirements. For defence-specific optical coating and surface requirements, the MIL-PRF-13830B guide covers clause phrasing.
A worked example
Say your sensor window drawing reads: “Cleanliness MIL-STD-1246C Level 100A.” Reading it as the standard intends, the part needs a particle count within Level 100 limits and an NVR level A. A complete RFQ line would add: “Revision C Notice 1; applies to both optical faces within the clear aperture; verified by tape lift to ASTM E1216 on uncoated face and by agreed non-contact method on the coated face; NVR by solvent wash; report counts per size bin; pack in double cleanroom bags.” Every addition removes a point on which a quote and an inspection result could diverge.
Promo: precision glass built to be specified and audited
We manufacture custom glass components for defence, aerospace, medical device, automotive, lighting, electronics and marine customers, from cutting, CNC machining and edge finishing to coated, toughened and laminated glass, display glass and optical windows. Our production is ISO 9001 certified, traceable at batch level and scalable from prototype to volume, with advanced inspection and documented export compliance. Send us your drawing with the cleanliness note as written and we will work through the specification with you at quotation stage.

See the full range on our glass fabrication and finishing services page, or browse our optical components.
Perspective
In our experience of specification-driven procurement, a cleanliness requirement is only as good as the sentence that carries it. A level number without a revision, a surface and a verification point leaves three decisions to whoever opens the box.
We build our work around the things that make a specification auditable: ISO 9001 certification, batch-level traceability, tight tolerances and advanced inspection. Traceability matters here because a cleanliness result is tied to a lot, a surface and a date. When the record shows which batch a part came from, a failed count can be investigated instead of argued about.
Our advice to engineering and procurement teams is to raise the cleanliness note at the prototype stage. Prototype to volume is a path we support, and the cleanliness, packaging and reporting terms settled on the first order carry through to the series. That way the requirement you validate is the one you receive in production.
Alexandra
FAQ
Is MIL-STD-1246C still valid?
No. It is recorded as cancelled on 15 February 2002 and superseded by IEST-STD-CC1246, and the current edition is IEST-STD-CC1246E. It remains relevant because older contracts and drawings still cite it. Confirm with your customer which document governs.
What does “MIL-STD-1246 Level 100” mean?
It means a maximum particle count per 0.1 m² of surface in each size band, for example 1,930 particles of 5 µm or larger and 1.08 of 100 µm or larger. Any NVR letter or optional limit that follows is a separate requirement. The full table is in the standard.
Is a cleanroom class the same as a product cleanliness level?
No. A cleanroom class such as ISO 7 limits particles in the air per cubic metre. A product cleanliness level limits particles and residue on a surface per 0.1 m². A part needs a specification for each if both matter.
How do you test for MIL-STD-1246C cleanliness?
Particles are sampled by tape lift to ASTM E1216 and NVR by solvent flush or wash, or by demonstrated equivalents, and results are reported per 0.1 m². Agree the method for coated or delicate surfaces before ordering, because sensitive surfaces must not be tape-lifted.
Sources
- Military Standard 1246C, Product Cleanliness Levels and Contamination Control Program
- ECSS-Q-70-01A, Space product assurance (ESA)
- ECSS-Q-70-01A tape-lift requirements
- DLA ASSIST-QuickSearch record for MIL-STD-1246
- OSTI report on the history of MIL-STD-1246
- IEST-STD-CC1246E
- NASA JPL quality clause QC67
- SAE AMS-03-2C material specification
- ISO Class 7 cleanroom requirements
- ISO 4406 chart and cleanliness guide



